Multiple Solar Panels To Charge Controller

To meet high power charging requirements several solar controllers can be connected in parallel to a battery bank with each controller connected to its own separate pv subarray.
Multiple solar panels to charge controller. I ve a question regarding hooking up multiple units of the solar mppt charge controller if your load requirement is such that then you need multiple mppt charge controller for your pv system. So the worry is that if solar panels are running at the same time will they overcharge the battery because it now has two sources charging it. On my boat i would add dc plugs for both batteries to connect the charge controllers. Multiple panels an array to a single controller is fine providing wiring is done right for the controller used.
I see that in xantrex manuals that you have to hook up separate arrays no mixup to each charge controller and hence consequently to the separate. The only time the voltages add together is when they are in series like in each row. You should think of a charge controller in this same sense. The solar panel disconnect switch is required because the batteries should be connected to the charge controllers before the solar panel is connected.
2 panels that produce 12 volts each in series produces a total of 24 volts. Multiple charge controllers esp. In addition to displaying information from any individual controller or aggregated system totals it allows simultaneous initiation of an equalization charging cycle for all tristar or tristar mppt solar charge controllers in the system. The meterhub was designed specifically for systems with multiple controllers.
Figure out how many solar panels you are going to need for your home first. In fact by wiring several solar panels in series we increase the voltage keeping the same current while wiring them in parallel we increase the current keeping the same voltage. Mppt type connected to a single panel array can be an issue and should generally be avoided. The connection of multiple solar panels in parallel arises from the need to reach certain current values at the output without changing the voltage.
Instead of buying 2 smaller panels one for each battery bank i was thinking about hooking up 2 charge controllers to the same solar panel. Multiple charging sources to a single battery bank is generally fine. Because each row provides the same voltage and they are in parallel the total voltage to the charge controller is 24. Well assuming there is a charge controller fitted on the solar installation then both charge sources the battery charger and the solar system are regulated.
They are of different brands but will be mounted in the same direction. The solar panels are both 12 but one is 80w and the other is 120w.