Nc Deck Roof Snow And Dead Loads

Wind uplift pressures c.
Nc deck roof snow and dead loads. In regions with heavy snowfall the snow load may exceed the 40 psf live load. Purpose of this web site. D dead load l live load l r live roof load w wind load s snow load e earthquake load r rainwater load or ice water load. The north zone middle zone and the south zone are identified on the roof load zone.
Roof loads are a downward vertical force on the home. The reactions resulting from the dead load and live load specified in table 1607 1 or the snow load specified in section 1608 in accordance with section 1605 acting on the cantilevered portion of the deck and no live load or snow load on the remaining portion of the deck. In those instances allowable spans for larger live loads can substitute for an equivalent snow load. Roofing criteria state of north carolina pat mccrory governor department of administration kathryn johnston acting secretary.
The dead load on a roof is the weight of the roof structure itself along with any permanently attached materials or structures on the roof so it must be designed first of all to. In areas of the state outside of certified local government jurisdictions the design snow load shall be based on the ground snow loads developed in snow loads for structural design in montana authored by f f. For residential decks designed for entertaining large groups it s not a bad idea to overbuild it from the minimum 40 psf required by building codes. This is usually about 10 psf.
The load that is placed on your deck is expressed in pounds per square foot psf and the total load or more appropriately the design load is comprised of the dead load and the live load. Schilke civil agricultural engineering montana state university august 1989. Victor staley a building official in the town of brewster mass responds. Used but they typically defined the load cases or combination stress or strength limits and deflection limits.
The roof shall be designed for the live load indicated in table r301 6 or the snow load indicated. The minimum design roof snow load. However a south roof load zone home cannot be installed in either a middle or north roof load zone. This issue of live load vs.
Load types loads used in design load equations are given letters by type. The deck supports the non load bearing components such as insulation membrane flashing etc. The purpose of this web site is to provide ground snow load analysis information and data gathered from all 50 states. Dead load is basically the load created by the weight of the deck itself.